Udsalget slutter om
Udvidet returret til d. 31. januar 2025

Influence of Plasticizer¿s on Biomimetic Potentio Atrazine sensor - Saumya Varghese - Bog

Influence of Plasticizer¿s on Biomimetic Potentio Atrazine sensoraf Saumya Varghese
Bag om Influence of Plasticizer¿s on Biomimetic Potentio Atrazine sensor

Plasticizers are commonly used in sensor fabrication to improve the mechanical properties and flexibility of the sensing materials. However, the choice of plasticizer can influence the performance and sensing characteristics of the biomimetic potentiometric sensor for atrazine. Different plasticizers can affect the sensitivity, selectivity, and response time of the sensor.The potential response of the sensor was studied using different plasticisers Dioctyl phthalate, DOP and Bis(2-ethyl hexyl)sebacate, BEHS. The sensor with BEHS shows a better Nernstian response in the range of 10-4 M - 10-8 M with a limit of detection 1×10-8 M and a slope of 56.2 mV. The newly created sensor has a dynamic response time of one minute and fifty seconds, and conditioning the sensor in a buffer containing 0.1 M acetic acid is necessary to obtain more accurate, repeatable findings.This study describes how plasticizers affected the design of a biomimetic potentiometric atrazine sensor.

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9786205523513
  • Indbinding:
  • Paperback
  • Sideantal:
  • 52
  • Udgivet:
  • 25. maj 2023
  • Størrelse:
  • 150x4x220 mm.
  • Vægt:
  • 96 g.
  • 2-3 uger.
  • 16. december 2024
På lager
Forlænget returret til d. 31. januar 2025

Normalpris

  • BLACK FRIDAY
    : :

Medlemspris

Prøv i 30 dage for 45 kr.
Herefter fra 79 kr./md. Ingen binding.

Beskrivelse af Influence of Plasticizer¿s on Biomimetic Potentio Atrazine sensor

Plasticizers are commonly used in sensor fabrication to improve the mechanical properties and flexibility of the sensing materials. However, the choice of plasticizer can influence the performance and sensing characteristics of the biomimetic potentiometric sensor for atrazine. Different plasticizers can affect the sensitivity, selectivity, and response time of the sensor.The potential response of the sensor was studied using different plasticisers Dioctyl phthalate, DOP and Bis(2-ethyl hexyl)sebacate, BEHS. The sensor with BEHS shows a better Nernstian response in the range of 10-4 M - 10-8 M with a limit of detection 1×10-8 M and a slope of 56.2 mV. The newly created sensor has a dynamic response time of one minute and fifty seconds, and conditioning the sensor in a buffer containing 0.1 M acetic acid is necessary to obtain more accurate, repeatable findings.This study describes how plasticizers affected the design of a biomimetic potentiometric atrazine sensor.

Brugerbedømmelser af Influence of Plasticizer¿s on Biomimetic Potentio Atrazine sensor



Find lignende bøger
Bogen Influence of Plasticizer¿s on Biomimetic Potentio Atrazine sensor findes i følgende kategorier:

Gør som tusindvis af andre bogelskere

Tilmeld dig nyhedsbrevet og få gode tilbud og inspiration til din næste læsning.