Vi bøger
Levering: 1 - 2 hverdage

Development of CADx System for detection of anomalies in breast - Ankita Singh - Bog

Development of CADx System for detection of anomalies in breastaf Ankita Singh
Bag om Development of CADx System for detection of anomalies in breast

A dataset of 322 images from Mammographic Image Analysis Society (MIAS). The images are pre-processed with Adaptive Median filter for noise removal and image enhancement. For ROI extraction original image having 1024 x1024 pixels are cropped into 256x256 pixels. The images are segmented using Gaussian Mixture Model for extracting the actual tumour area. We have considered 20 benign, 20 malignant and 20 normal images cases of circumscribed, speculated and ill-defined masses from the database. Each mass is represented with 22 texture features. The PNN classifier is used to perform the classification tasks on 60 images. The input images are classified into three different training ¿testing datasets as 50-50%,70-30% and 80-20%. With the help of PNN classifier, Sensitivity, Specificity and Accuracy are calculated for each of the dataset. For 50-50% training-testing dataset, Specificity, Sensitivity and Accuracy obtaining are 50%, 50% and 50% respectively. For 70-30% training-testing dataset, Specificity, Sensitivity and Accuracy obtaining are 75%, 100% and 100% respectively. 80-20% training-testing dataset gave the promising results with the Specificity, Sensitivity and Accuracy of 100%

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9786139828913
  • Indbinding:
  • Paperback
  • Sideantal:
  • 84
  • Udgivet:
  • 23. juni 2020
  • Størrelse:
  • 150x6x220 mm.
  • Vægt:
  • 143 g.
  • 2-3 uger.
  • 19. december 2024
På lager
Forlænget returret til d. 31. januar 2025

Normalpris

Medlemspris

Prøv i 30 dage for 45 kr.
Herefter fra 79 kr./md. Ingen binding.

Beskrivelse af Development of CADx System for detection of anomalies in breast

A dataset of 322 images from Mammographic Image Analysis Society (MIAS). The images are pre-processed with Adaptive Median filter for noise removal and image enhancement. For ROI extraction original image having 1024 x1024 pixels are cropped into 256x256 pixels. The images are segmented using Gaussian Mixture Model for extracting the actual tumour area. We have considered 20 benign, 20 malignant and 20 normal images cases of circumscribed, speculated and ill-defined masses from the database. Each mass is represented with 22 texture features. The PNN classifier is used to perform the classification tasks on 60 images. The input images are classified into three different training ¿testing datasets as 50-50%,70-30% and 80-20%. With the help of PNN classifier, Sensitivity, Specificity and Accuracy are calculated for each of the dataset. For 50-50% training-testing dataset, Specificity, Sensitivity and Accuracy obtaining are 50%, 50% and 50% respectively. For 70-30% training-testing dataset, Specificity, Sensitivity and Accuracy obtaining are 75%, 100% and 100% respectively. 80-20% training-testing dataset gave the promising results with the Specificity, Sensitivity and Accuracy of 100%

Brugerbedømmelser af Development of CADx System for detection of anomalies in breast



Find lignende bøger
Bogen Development of CADx System for detection of anomalies in breast findes i følgende kategorier:

Gør som tusindvis af andre bogelskere

Tilmeld dig nyhedsbrevet og få gode tilbud og inspiration til din næste læsning.