Vi bøger
Levering: 1 - 2 hverdage

Effect of Uneven Cooling on Performance of Air-Cooled Condenser - Hans Georg Schrey - Bog

Bag om Effect of Uneven Cooling on Performance of Air-Cooled Condenser

Scientific Essay from the year 2017 in the subject Physics - Thermodynamics, , course: Heat transfer engineering, language: English, abstract: Air-cooled condensers (¿ACC¿) operating in vacuum are widely used at the cold end of contemporary thermal power plants. Proper functioning of the condenser is paramount for power plant efficiency. To adapt to changing process conditions because of changed ambient air temperature or power station load ACC streets are either taken out of or into service or, module fan speed settings are selected appropriately. Even if all fans are running at same speed local variations of cooling air flow may arise as a consequence of e.g. fan location or local wind impact. The designer must ensure that no negative effect (i.e. no cold spot) may evolve at the steam side of the ACC caused by uneven air side cooling or fan control. The following note describes a theoretical method to assess the effect of air flow variations on ACC performance and provides simple rules to avoid potentially risky situations. An important role for safe operation plays the size of the secondary condenser. The procedure may be used as a guideline for proper sizing of the secondary condenser with respect to airflow maldistribution.

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9783668676176
  • Indbinding:
  • Paperback
  • Sideantal:
  • 28
  • Udgivet:
  • 4. April 2018
  • Udgave:
  • 18001
  • Størrelse:
  • 148x3x210 mm.
  • Vægt:
  • 56 g.
  • 2-3 uger.
  • 30. Oktober 2024
På lager

Normalpris

Medlemspris

Prøv i 30 dage for 45 kr.
Herefter fra 79 kr./md. Ingen binding.

Beskrivelse af Effect of Uneven Cooling on Performance of Air-Cooled Condenser

Scientific Essay from the year 2017 in the subject Physics - Thermodynamics, , course: Heat transfer engineering, language: English, abstract: Air-cooled condensers (¿ACC¿) operating in vacuum are widely used at the cold end of contemporary thermal power plants. Proper functioning of the condenser is paramount for power plant efficiency.
To adapt to changing process conditions because of changed ambient air temperature or power station load ACC streets are either taken out of or into service or, module fan speed settings are selected appropriately. Even if all fans are running at same speed local variations of cooling air flow may arise as a consequence of e.g. fan location or local wind impact. The designer must ensure that no negative effect (i.e. no cold spot) may evolve at the steam side of the ACC caused by uneven air side cooling or fan control.
The following note describes a theoretical method to assess the effect of air flow variations on ACC performance and provides simple rules to avoid potentially risky situations. An important role for safe operation plays the size of the secondary condenser. The procedure may be used as a guideline for proper sizing of the secondary condenser with respect to airflow maldistribution.

Brugerbedømmelser af Effect of Uneven Cooling on Performance of Air-Cooled Condenser



Find lignende bøger
Bogen Effect of Uneven Cooling on Performance of Air-Cooled Condenser findes i følgende kategorier:

Gør som tusindvis af andre bogelskere

Tilmeld dig nyhedsbrevet og få gode tilbud og inspiration til din næste læsning.